Files
OpenCellular/common
Shawn Nematbakhsh e4deceba8d charger: Prevent SET access to EC_CMD_CHARGE_STATE on locked systems
The SET sub-command of EC_CMD_CHARGE_STATE sets charger current /
voltage parameters to arbitrary values and should be locked down.
EC_CMD_CHARGE_CONTROL, on the other hand, switches between several safe
operation modes, and should be allowed.

BUG=None
TEST=On kevin, set force_locked, plug zinger, and verify:
ectool chargestate param 4 3 <-- ACCESS_DENIED
ectool chargestate show <-- prints params
ectool chargecontrol idle <-- stops charging battery
ectool chargecontrol normal <-- battery charges again
BRANCH=None

Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Change-Id: I5503f07bb196d023a9bcd2e33f2e247f061f05e5
Reviewed-on: https://chromium-review.googlesource.com/757237
Commit-Ready: Shawn N <shawnn@chromium.org>
Tested-by: Shawn N <shawnn@chromium.org>
Reviewed-by: Randall Spangler <rspangler@chromium.org>
2017-11-09 16:43:54 -08:00
..