Shawn Nematbakhsh ea3dbb98b4 charge_manager: Minimize log spew
Previously, we tried to minimize log spew by keeping track of previous
log entries and not writing new entries in some cases. Instead, we can
write a log on the following events only:

1. A port becomes active or
2. A port becomes inactive or
3. The active charge port power limit changes or
4. Any supplier change on an inactive port

Also, make charge_manager_save_log a non-static charge manager API
function, so that other modules can record a log, if they have reason to
believe a port has changed outside of a charge manager change.

BUG=chrome-os-partner:33248
TEST=Manual on Samus. Make various power actions and observe logging.
BRANCH=Samus

Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Change-Id: I5d5d3e186e85fdb1c59797ffbfb2f5a6ec04d94d
Reviewed-on: https://chromium-review.googlesource.com/247891
Reviewed-by: Alec Berg <alecaberg@chromium.org>
2015-02-11 04:48:37 +00:00
2015-02-11 04:48:37 +00:00
2015-02-11 04:48:37 +00:00
2015-02-10 08:46:06 +00:00
2014-03-31 22:45:09 +00:00
2012-05-11 09:11:52 -07:00
2015-01-08 23:55:58 +00:00
2014-04-02 19:58:53 +00:00
2014-05-15 05:20:14 +00:00

For an overview of the Embedded Controller firmware, refer to

http://www.chromium.org/chromium-os/2014-firmware-summit