Open drain cleanup minimizes leakage and signal glitching on shared
reset/signal lines, and is tidier than explicitly switching the
signals between inputs/outputs.
Touchscreen and lightbar are powered by +5VALW so their signals need
to be dropped when +5VALW is off to avoid leakage, and so they see a
clean reset signal when they're powered up.
Moved +5VALW power-on to S5-S3 transition, to minimize power draw in
S5. This also ensures that 5VALW-powered devices get reset when the
device bounces through S5. (No effect on proto1, where 5VALW is not
under EC control.)
Signed-off-by: Randall Spangler <rspangler@chromium.org>
BUG=chrome-os-partner:9172
TEST=boot and shutdown system; still works.