Vijay Hiremath f66113247a charge_state_v2: Limit i/p current to meet allowed MAX i/p system power
If battery is not present, input current is set to PD_MAX_CURRENT_MA.
If the input power set is greater than the maximum allowed system power,
system might get damaged. Hence, limit the input current to meet maximum
allowed input system power.

BUG=chrome-os-partner:58498
BRANCH=none
TEST=Manually tested on Reef. Removed the battery & using 'charger'
     console command observed the following.
     With Zinger charger at 20V - Input current is set to 2.25A
     With Type-C & other chargers - Input current is set to 3A

Change-Id: Ife8686f322e095aa74b740a7c469bfe87107fb9a
Signed-off-by: Vijay Hiremath <vijay.p.hiremath@intel.com>
Reviewed-on: https://chromium-review.googlesource.com/397865
Commit-Ready: Vijay P Hiremath <vijay.p.hiremath@intel.com>
Tested-by: Vijay P Hiremath <vijay.p.hiremath@intel.com>
Reviewed-by: Shawn N <shawnn@chromium.org>