cv: Add tr398 automation test

This will launch and configure tr398 and gather the results
in the end, similar to other chamber-view tests.

This one utilizes a config file to store the calibration and radio
and attenuator config, see example-configs/tr398-ferndale-ac-cfg.txt

A new calibration file would need to be used for your own testbed.

Signed-off-by: Ben Greear <greearb@candelatech.com>
This commit is contained in:
Ben Greear
2021-04-16 14:43:03 -07:00
parent f3de09251d
commit a3e84ddeb1
2 changed files with 454 additions and 0 deletions

View File

@@ -0,0 +1,43 @@
# Example radio setup, calibration data, and attenuator setup.
# At least the attenuation will be unique for your testbed
# so run the calibration step, view the config, and paste the appropriate
# lines into a file similar to this.
radio-0: 1.1.2 wiphy0
radio-1: 1.1.3 wiphy1
radio-2: 1.1.4 wiphy2
radio-3: 1.1.5 wiphy3
radio-4: 1.1.6 wiphy4
radio-5: 1.1.7 wiphy5
rssi_0_2-0: -26
rssi_0_2-1: -26
rssi_0_2-2: -26
rssi_0_2-3: -26
rssi_0_2-4: -27
rssi_0_2-5: -27
rssi_0_2-6: -27
rssi_0_2-7: -27
rssi_0_2-8: -25
rssi_0_2-9: -25
rssi_0_2-10: -25
rssi_0_2-11: -25
rssi_0_5-0: -38
rssi_0_5-1: -38
rssi_0_5-2: -38
rssi_0_5-3: -38
rssi_0_5-4: -38
rssi_0_5-5: -38
rssi_0_5-6: -38
rssi_0_5-7: -38
rssi_0_5-8: -47
rssi_0_5-9: -47
rssi_0_5-10: -47
rssi_0_5-11: -47
atten-0: 1.1.85.0
atten-1: 1.1.85.1
atten-2: 1.1.85.2
atten-3: 1.1.85.3
atten-4: 1.1.1002.0
atten-5: 1.1.1002.1
atten-8: 1.1.1002.2
atten-9: 1.1.1002.3

411
py-scripts/lf_tr398_test.py Executable file
View File

@@ -0,0 +1,411 @@
#!/usr/bin/env python3
"""
Note: To Run this script gui should be opened with
path: cd LANforgeGUI_5.4.3 (5.4.3 can be changed with GUI version)
pwd (Output : /home/lanforge/LANforgeGUI_5.4.3)
./lfclient.bash -cli-socket 3990
This script is used to automate running TR398 tests. You
may need to view a TR398 test configured through the GUI to understand
the options and how best to input data.
./lf_tr398_test.py --mgr localhost --port 8080 --lf_user lanforge --lf_password lanforge \
--instance_name tr398-instance --config_name test_con \
--upstream 1.2.eth2 \
--dut5 'TR398-DUT ruckus750-5 4c:b1:cd:18:e8:ec (1)' \
--dut2 'TR398-DUT ruckus750-2 4c:b1:cd:18:e8:e8 (2)' \
--raw_lines_file example-configs/tr398-ferndale-ac-cfg.txt \
--set 'Calibrate Attenuators' 0 \
--set 'Receiver Sensitivity' 0 \
--set 'Maximum Connection' 1 \
--set 'Maximum Throughput' 1 \
--set 'Airtime Fairness' 0 \
--set 'Range Versus Rate' 0 \
--set 'Spatial Consistency' 0 \
--set 'Multiple STAs Performance' 0 \
--set 'Multiple Assoc Stability' 0 \
--set 'Downlink MU-MIMO' 0 \
--set 'AP Coexistence' 0 \
--set 'Long Term Stability' 0
Note:
--raw_line 'line contents' will add any setting to the test config. This is
useful way to support any options not specifically enabled by the
command options.
--set modifications will be applied after the other config has happened,
so it can be used to override any other config. Above, we are disabling many
of the subtests, and enablign just Maximum Connection and Maximum Throughput
tests.
The RSSI values are calibrated, so you will need to run the calibration step and
call with appropriate values for your particular testbed. This is loaded from
example-configs/tr398-ferndale-ac-cfg.txt in this example.
Contents of that file is a list of raw lines, for instance:
rssi_0_2-0: -26
rssi_0_2-1: -26
rssi_0_2-2: -26
....
Example of raw text config for TR-398, to show other possible options:
show_events: 1
show_log: 0
port_sorting: 0
kpi_id: TR_398
notes0: Standard LANforge TR-398 automation setup, DUT is in large chamber CT840a, LANforge test system is in
notes1: smaller CT810a chamber. CT704b and CT714 4-module attenuators are used. Directional antennas
notes2: mounted on the sides of the DUT chamber are used to communicate to the DUT. DUT is facing forward at
notes3: the zero-rotation angle.
bg: 0xE0ECF8
test_rig: TR-398 test bed
show_scan: 1
auto_helper: 1
skip_2: 0
skip_5: 0
skip_5b: 1
skip_dual: 0
skip_tri: 1
selected_dut5: TR398-DUT ruckus750-5 4c:b1:cd:18:e8:ec (1)
selected_dut2: TR398-DUT ruckus750-2 4c:b1:cd:18:e8:e8 (2)
upstream_port: 1.2.2 eth2
operator:
mconn: 5
band2_freq: 2437
band5_freq: 5180
tos: 0
speed: 65%
speed_max_cx_2: 2000000
speed_max_cx_5: 8000000
max_tput_speed_2: 100000000
max_tput_speed_5: 560000000
rxsens_deg_rot: 45
rxsens_pre_steps: 8
stability_udp_dur: 3600
stability_iter: 288
calibrate_mode: 4
calibrate_nss: 1
dur120: 120
dur180: 180
i_5g_80: 195000000
i_5g_40: 90000000
i_2g_20: 32000000
spatial_deg_rot: 30
spatial_retry: 0
reset_pp: 99
rxsens_stop_at_pass: 0
auto_coex: 1
rvr_adj: 0
rssi_2m_2: -20
rssi_2m_5: -32
extra_dl_path_loss: 3
dur60: 60
turn_table: TR-398
radio-0: 1.1.2 wiphy0
radio-1: 1.1.3 wiphy1
radio-2: 1.1.4 wiphy2
radio-3: 1.1.5 wiphy3
radio-4: 1.1.6 wiphy4
radio-5: 1.1.7 wiphy5
rssi_0_2-0: -26
rssi_0_2-1: -26
rssi_0_2-2: -26
rssi_0_2-3: -26
rssi_0_2-4: -27
rssi_0_2-5: -27
rssi_0_2-6: -27
rssi_0_2-7: -27
rssi_0_2-8: -25
rssi_0_2-9: -25
rssi_0_2-10: -25
rssi_0_2-11: -25
rssi_0_5-0: -38
rssi_0_5-1: -38
rssi_0_5-2: -38
rssi_0_5-3: -38
rssi_0_5-4: -38
rssi_0_5-5: -38
rssi_0_5-6: -38
rssi_0_5-7: -38
rssi_0_5-8: -47
rssi_0_5-9: -47
rssi_0_5-10: -47
rssi_0_5-11: -47
atten-0: 1.1.85.0
atten-1: 1.1.85.1
atten-2: 1.1.85.2
atten-3: 1.1.85.3
atten-4: 1.1.1002.0
atten-5: 1.1.1002.1
atten-8: 1.1.1002.2
atten-9: 1.1.1002.3
atten_cal: 1
rxsens: 0
max_cx: 0
max_tput: 0
atf: 0
rvr: 0
spatial: 0
multi_sta: 0
reset: 0
mu_mimo: 0
stability: 0
ap_coex: 0
"""
import sys
import os
import argparse
import time
import json
from os import path
if sys.version_info[0] != 3:
print("This script requires Python 3")
exit(1)
if 'py-json' not in sys.path:
sys.path.append(os.path.join(os.path.abspath('..'), 'py-json'))
from cv_test_manager import cv_test as cvtest
from cv_commands import chamberview as cv
from cv_test_reports import lanforge_reports as lf_rpt
class DataplaneTest(cvtest):
def __init__(self,
lf_host="localhost",
lf_port=8080,
lf_user="lanforge",
lf_password="lanforge",
instance_name="tr398_instance",
config_name="tr398_config",
upstream="1.2.eth2",
pull_report=False,
load_old_cfg=False,
raw_lines_file="",
dut5="",
dut2="",
enables=[],
disables=[],
raw_lines=[],
sets=[],
):
super().__init__(lfclient_host=lf_host, lfclient_port=lf_port)
self.lf_host = lf_host
self.lf_port = lf_port
self.lf_user = lf_user
self.lf_password =lf_password
self.createCV = cv(lf_host, lf_port);
self.instance_name = instance_name
self.config_name = config_name
self.dut5 = dut5
self.dut2 = dut2
self.raw_lines_file = raw_lines_file
self.upstream = upstream
self.pull_report = pull_report
self.load_old_cfg = load_old_cfg
self.test_name = "TR-398"
self.enables = enables
self.disables = disables
self.raw_lines = raw_lines
self.sets = sets
def setup(self):
# Nothing to do at this time.
return
def run(self):
self.createCV.sync_cv()
time.sleep(2)
self.createCV.sync_cv()
blob_test = "%s-"%(self.test_name)
self.rm_text_blob(self.config_name, blob_test) # To delete old config with same name
self.show_text_blob(None, None, False)
# Test related settings
cfg_options = []
# Read in calibration data and whatever else.
if self.raw_lines_file != "":
with open(self.raw_lines_file) as fp:
line = fp.readline()
while line:
cfg_options.append(line)
line = fp.readline()
fp.close()
for en in self.enables:
cfg_options.append("%s: 1"%(en[0]))
for en in self.disables:
cfg_options.append("%s: 0"%(en[0]))
for r in self.raw_lines:
cfg_options.append(r[0])
# cmd line args take precedence
if self.upstream != "":
cfg_options.append("upstream_port: " + self.upstream)
if self.dut5 != "":
cfg_options.append("selected_dut5: " + self.dut5)
if self.dut2 != "":
cfg_options.append("selected_dut2: " + self.dut2)
# We deleted the scenario earlier, now re-build new one line at a time.
for value in cfg_options:
self.create_test_config(self.config_name, blob_test, value)
# Request GUI update its text blob listing.
self.show_text_blob(self.config_name, blob_test, False)
# Hack, not certain if the above show returns before the action has been completed
# or not, so we sleep here until we have better idea how to query if GUI knows about
# the text blob.
time.sleep(5)
load_old = "false"
if self.load_old_cfg:
load_old = "true"
for i in range(60):
response = self.create_test(self.test_name, self.instance_name, load_old)
d1 = {k: v for e in response for (k, v) in e.items()}
if d1["LAST"]["response"] == "OK":
break
else:
time.sleep(1)
self.load_test_config(self.config_name, self.instance_name)
self.auto_save_report(self.instance_name)
# Apply 'sets'
for kv in self.sets:
cmd = "cv set '%s' '%s' '%s'" % (self.instance_name, kv[0], kv[1])
print("Running CV command: ", cmd)
self.run_cv_cmd(cmd)
response = self.start_test(self.instance_name)
d1 = {k: v for e in response for (k, v) in e.items()}
if d1["LAST"]["response"].__contains__("Could not find instance:"):
print("ERROR: start_test failed: ", d1["LAST"]["response"], "\n");
# pprint(response)
exit(1)
while (True):
check = self.get_report_location(self.instance_name)
location = json.dumps(check[0]["LAST"]["response"])
if location != "\"Report Location:::\"":
location = location.replace("Report Location:::", "")
self.close_instance(self.instance_name)
self.cancel_instance(self.instance_name)
location = location.strip("\"")
report = lf_rpt()
print(location)
try:
if self.pull_report:
report.pull_reports(hostname=self.lf_host, username=self.lf_user, password=self.lf_password,
report_location=location)
except:
raise Exception("Could not find Reports")
break
time.sleep(1)
self.rm_text_blob(self.config_name, blob_test) # To delete old config with same name
def main():
parser = argparse.ArgumentParser("""
Open this file in an editor and read the top notes for more details.
Example:
./lf_tr398_test.py --mgr localhost --port 8080 --lf_user lanforge --lf_password lanforge \
--instance_name tr398-instance --config_name test_con \
--upstream 1.2.eth2 \
--dut5 'TR398-DUT ruckus750-5 4c:b1:cd:18:e8:ec (1)' \
--dut2 'TR398-DUT ruckus750-2 4c:b1:cd:18:e8:e8 (2)' \
--raw_lines_file example-configs/tr398-ferndale-ac-cfg.txt \
--set 'Calibrate Attenuators' 0 \
--set 'Receiver Sensitivity' 0 \
--set 'Maximum Connection' 1 \
--set 'Maximum Throughput' 1 \
--set 'Airtime Fairness' 0 \
--set 'Range Versus Rate' 0 \
--set 'Spatial Consistency' 0 \
--set 'Multiple STAs Performance' 0 \
--set 'Multiple Assoc Stability' 0 \
--set 'Downlink MU-MIMO' 0 \
--set 'AP Coexistence' 0 \
--set 'Long Term Stability' 0
"""
)
parser.add_argument("-m", "--mgr", type=str, default="localhost",
help="address of the LANforge GUI machine (localhost is default)")
parser.add_argument("-o", "--port", type=int, default=8080,
help="IP Port the LANforge GUI is listening on (8080 is default)")
parser.add_argument("--lf_user", type=str, default="lanforge",
help="LANforge username to pull reports")
parser.add_argument("--lf_password", type=str, default="lanforge",
help="LANforge Password to pull reports")
parser.add_argument("-i", "--instance_name", type=str,
help="create test instance")
parser.add_argument("-c", "--config_name", type=str,
help="Config file name")
parser.add_argument("-u", "--upstream", type=str, default="1.1.eth2",
help="Upstream port for wifi capacity test ex. 1.1.eth2")
parser.add_argument("-r", "--pull_report", default=False, action='store_true',
help="pull reports from lanforge (by default: False)")
parser.add_argument("--load_old_cfg", default=False, action='store_true',
help="Should we first load defaults from previous run of the capacity test? Default is False")
parser.add_argument("--dut2", default="",
help="Specify 2Ghz DUT used by this test, example: 'TR398-DUT ruckus750-2 4c:b1:cd:18:e8:e8 (2)'")
parser.add_argument("--dut5", default="",
help="Specify 5Ghz DUT used by this test, example: 'TR398-DUT ruckus750-5 4c:b1:cd:18:e8:ec (1)'")
parser.add_argument("--enable", action='append', nargs=1, default=[],
help="Specify options to enable (set value to 1). Example: --enable show_log See example raw text config for possible options. May be specified multiple times.")
parser.add_argument("--disable", action='append', nargs=1, default=[],
help="Specify options to disable (set value to 0). Example: --disable show_events See example raw text config for possible options. May be specified multiple times.")
parser.add_argument("--set", action='append', nargs=2, default=[],
help="Specify options to set values based on their label in the GUI. Example: --set 'IP ToS:' 64 May be specified multiple times.")
parser.add_argument("--raw_line", action='append', nargs=1, default=[],
help="Specify lines of the raw config file. Example: --raw_line 'pkts: Custom;60;142;256;512;1024;MTU' See example raw text config for possible options. This is catch-all for any options not available to be specified elsewhere. May be specified multiple times.")
parser.add_argument("--raw_lines_file", default="",
help="Specify a file of raw lines to apply.")
args = parser.parse_args()
CV_Test = DataplaneTest(lf_host = args.mgr,
lf_port = args.port,
lf_user = args.lf_user,
lf_password = args.lf_password,
instance_name = args.instance_name,
config_name = args.config_name,
upstream = args.upstream,
pull_report = args.pull_report,
load_old_cfg = args.load_old_cfg,
dut2 = args.dut2,
dut5 = args.dut5,
raw_lines_file = args.raw_lines_file,
enables = args.enable,
disables = args.disable,
raw_lines = args.raw_line,
sets = args.set
)
CV_Test.setup()
CV_Test.run()
if __name__ == "__main__":
main()