Alec Berg 5f4ea79bb1 samus: use resulting current limit from charge manager
Send the current limit chosen by charge manager to the EC so
that it can set the current limit appropriately. Note, before
this change, only the PD negotiated current limit was sent to
EC.

BUG=none
BRANCH=samus
TEST=use a non-PD type-C charger and verify current limit gets
set appropriately on EC.

Change-Id: Ic4bfce052ec8150cad07d35e2cb2fcbfd3d3e6c8
Signed-off-by: Alec Berg <alecaberg@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/225667
Reviewed-by: Vincent Palatin <vpalatin@chromium.org>
2014-10-28 01:46:38 +00:00