Nicolas Boichat bce7b5b4b6 ectool: Print temperature unit in ectool temps output
Currently, 'ectool temps all|<n>' just prints "300". This may easily
be mistakenly read as tenth of degree C (30.0 C), as the value
appears to make sense (close to room temperature). However, the value
is actually 300 K (27 C).

CQ-DEPEND=CL:763578
BRANCH=none
BUG=chromium:783845
TEST=ectool temps all shows temperature unit (K)

Change-Id: I70f7f04d061cb1d4f741d59f8b48c7963dd8280f
Signed-off-by: Nicolas Boichat <drinkcat@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/763996
Reviewed-by: Shawn N <shawnn@chromium.org>
2017-11-11 12:13:42 -08:00
2017-08-07 19:29:13 -07:00
2017-11-10 18:45:50 -08:00
2017-07-08 20:38:53 -07:00
2017-10-10 22:13:43 -07:00
2017-11-03 19:17:49 -07:00
2017-11-09 16:43:54 -08:00
2012-05-11 09:11:52 -07:00
2017-11-09 11:53:13 -08:00
2014-04-02 19:58:53 +00:00
2015-12-08 20:05:05 -08:00

For an overview of the Embedded Controller firmware, refer to

http://www.chromium.org/chromium-os/2014-firmware-summit

For instructions on building from source, refer to

http://www.chromium.org/chromium-os/ec-development/getting-started-building-ec-images-quickly