Gwendal Grignou c0f78b4c0a motion: Add sample frequency per sensor
Store at which frequency each sensor should be sampled.
This frequency is different from the sensor frequency:
- sensor frequency: frequency at which the sensor produce information.
- sensor sampling frequency: frequency at the which the EC gater
information.
If 2 sensors must be sampled at very different frequency,
we don't want to oversample the slow one, and filling the
software FIFO unnecessarily.

BRANCH=smaug
TEST=Unit test. Check that frequency is correct when sensor
frequencies change from IIO driver.
BUG=chrome-os-partner:39900

Change-Id: I4272963413f53d4ca004e26639dc7a2affd317eb
Signed-off-by: Gwendal Grignou <gwendal@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/284616
Reviewed-by: Alec Berg <alecaberg@chromium.org>
2015-07-15 02:07:01 +00:00