On TCPC startup, set an alert to notify TCPM that we have been
reset. When TCPM gets this notification, it should re-send
initial TCPC parameters. If we were in a stable contract as
a sink, make sure we don't reset connection. If not, then
reset PD protocol state machine to the default state.
This fixes a bug where if the TCPC reboots while the TCPM is
still running, then the TCPC would not get re-initialized and
therefore no PD communication would not work. This also fixes
it such that if we are in a stable contract as a sink and the
TCPC reboots, then we don't lose power.
BUG=chrome-os-partner:46676
BRANCH=none
TEST=tested on glados. reboot PD MCU with and without a charger
plugged in and verify that PD communication works after the
reboot. verify that with a charger, we don't lose power.
also tested with a hoho plugged in during reboot.
Change-Id: I84fec4577b0daf5891bd8461d3f3d925014a5ecf
Signed-off-by: Alec Berg <alecaberg@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/307187
Reviewed-by: Shawn N <shawnn@chromium.org>