Vincent Palatin 4293de83e0 pd: fix PDO selection for low voltage boards
When the policy of the board is to select lowest voltage providing
enough power, the current algorithm ignores the fact that the board
input current limit might be lower than the charger maximum current for
a particular voltage level leading to the possibility of selected a
voltage with a lower available power.

Signed-off-by: Vincent Palatin <vpalatin@chromium.org>

BRANCH=none
BUG=none
TEST=set a Ryu board with the following configuration :
PD_PREFER_LOW_VOLTAGE
PD_MAX_POWER_MW       24000
PD_MAX_CURRENT_MA     1000
PD_MAX_VOLTAGE_MV     20000
connect it a Zinger (offering 3A @ 20V, 3A @ 12V and 3A @ 5V),
see it selecting 20V rather 12V before the patch.

Change-Id: I8c0589bb5e5705c4d8a6035120d1cdfaacaa14df
Reviewed-on: https://chromium-review.googlesource.com/269262
Reviewed-by: Vic Yang <victoryang@chromium.org>
Reviewed-by: Alec Berg <alecaberg@chromium.org>
Commit-Queue: Vincent Palatin <vpalatin@chromium.org>
Tested-by: Vincent Palatin <vpalatin@chromium.org>
2015-05-05 16:54:35 +00:00
..
2013-12-20 05:07:58 +00:00
2014-05-21 20:32:17 +00:00
2014-05-21 20:32:17 +00:00
2014-05-21 20:32:17 +00:00
2014-05-21 20:32:17 +00:00
2014-03-06 21:32:57 +00:00
2015-04-07 23:20:14 +00:00
2013-10-25 20:12:49 +00:00
2014-05-21 20:32:17 +00:00
2014-05-21 20:32:17 +00:00
2013-12-19 00:12:28 +00:00
2014-03-06 21:33:09 +00:00
2015-05-02 16:49:05 +00:00
2014-01-14 09:19:45 +00:00
2015-03-31 23:00:33 +00:00
2014-05-21 20:32:17 +00:00
2015-02-25 08:44:58 +00:00
2014-05-17 20:14:17 +00:00
2013-12-19 00:12:28 +00:00
2014-05-21 20:32:17 +00:00
2014-05-21 20:32:17 +00:00