Douglas Anderson da9c06a2e7 kevin / gru: Enable PD on SHI signals
The SHI lines connected from the EC to the AP and the AP might not be
turned on.  We should have a pull down on these lines to avoid them
glitching when the AP is in S3 or S5.

BRANCH=None
BUG=chrome-os-partner:56683
TEST=Verify S3/S5 power is decreased, and SHI interface is still
functional in S0 and on sysjump.

Change-Id: I3a9b018e6e8a5eddb1f23e004f1af3da3e503709
Signed-off-by: Douglas Anderson <dianders@chromium.org>
Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/376360
Tested-by: Shawn N <shawnn@chromium.org>
Reviewed-by: Aseda Aboagye <aaboagye@chromium.org>
Reviewed-by: Mulin Chao <mlchao@nuvoton.com>
2016-09-01 19:53:01 -07:00
2012-05-11 09:11:52 -07:00
2016-07-11 21:27:46 -07:00
2014-04-02 19:58:53 +00:00
2015-12-08 20:05:05 -08:00