Files
OpenCellular/board
Vijay Hiremath 3f9ee35859 BD99955: System VR in battery LEARN, Cut-off & No-battery condition
Regulate the system voltage by setting the charging voltage to battery
maximum in case of battery LEARN, Cut-off & No-battery conditions.

BUG=chrome-os-partner:55292, chrome-os-partner:55255
BRANCH=none
TEST=Manually tested on Amenia using console command charger.
     Charging voltage is set to battery max in LEARN, Cut-off &
     No-battery conditions.

Change-Id: I74bbab8174fd63b5f8439b8b35098db4a506d72d
Signed-off-by: Vijay Hiremath <vijay.p.hiremath@intel.com>
Reviewed-on: https://chromium-review.googlesource.com/360681
Commit-Ready: Shawn N <shawnn@chromium.org>
Tested-by: Vijay P Hiremath <vijay.p.hiremath@intel.com>
Tested-by: Divya S Sasidharan <divya.s.sasidharan@intel.com>
Reviewed-by: Shawn N <shawnn@chromium.org>
2016-07-18 13:33:04 -07:00
..
2016-07-12 15:36:53 -07:00
2016-07-14 23:34:38 -07:00
2016-07-15 21:39:16 -07:00
2016-05-04 16:15:02 -07:00
2014-04-02 19:58:53 +00:00