Files
OpenCellular/board
Shawn Nematbakhsh 3a3834ab34 kevin / gru: Add custom charge profile
- Stop charging when thermal limits are violated.
- Don't start charging if battery percent is above 95% (but continue to
  charge if we're already charging).
- Don't allow battery voltage to get too close (10mA) to BD9995X VBAT
  setting. If battery voltage exceeds VBAT then back boosting may occur.

BUG=chrome-os-partner:56255
BRANCH=gru
TEST=Manual on kevin, insert charger with battery at 97%, verify battery
doesn't charge and reported current is 0. Discharge down to 95% and
insert charger, verify battery charges. Charge to 100%, verify battery
stops requesting current.

Change-Id: Icc5641e88bfad7d9d8ad4b6840338541fe7ba9a8
Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/403483
Reviewed-by: Aseda Aboagye <aaboagye@chromium.org>
Reviewed-on: https://chromium-review.googlesource.com/415494
Commit-Ready: Shawn N <shawnn@chromium.org>
Tested-by: Shawn N <shawnn@chromium.org>
Reviewed-by: Shawn N <shawnn@chromium.org>
2016-12-01 19:59:03 -08:00
..
2016-07-19 16:31:58 -07:00
2016-10-19 02:45:36 -07:00
2016-11-15 17:41:53 -08:00
2016-11-02 17:39:56 -07:00
2016-11-02 17:39:56 -07:00
2016-05-04 16:15:02 -07:00
2014-04-02 19:58:53 +00:00