- Stop charging when thermal limits are violated. - Don't start charging if battery percent is above 95% (but continue to charge if we're already charging). - Don't allow battery voltage to get too close (10mA) to BD9995X VBAT setting. If battery voltage exceeds VBAT then back boosting may occur. BUG=chrome-os-partner:56255 BRANCH=gru TEST=Manual on kevin, insert charger with battery at 97%, verify battery doesn't charge and reported current is 0. Discharge down to 95% and insert charger, verify battery charges. Charge to 100%, verify battery stops requesting current. Change-Id: Icc5641e88bfad7d9d8ad4b6840338541fe7ba9a8 Signed-off-by: Shawn Nematbakhsh <shawnn@chromium.org> Reviewed-on: https://chromium-review.googlesource.com/403483 Reviewed-by: Aseda Aboagye <aaboagye@chromium.org> Reviewed-on: https://chromium-review.googlesource.com/415494 Commit-Ready: Shawn N <shawnn@chromium.org> Tested-by: Shawn N <shawnn@chromium.org> Reviewed-by: Shawn N <shawnn@chromium.org>